Crown Boiler BWC120 Spezifikationen

Stöbern Sie online oder laden Sie Spezifikationen nach Warmwasserbereiter & Kessel Crown Boiler BWC120 herunter. Crown Boiler BWC120 Specifications Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 28
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
Bimini Buddy
NEAR-BOILER PIPING MODULE
INSTALLATION INSTRUCTIONS
Models:
BB100H•
BB100I•
BB100C•
WARNING: Improper installation, adjustment, alteration,
service or maintenance can cause property damage,
injury, or loss of life. For assistance or additional informa-
tion, consult a qualied installer, service agency or the
gas supplier.
Manufacturer of Hydronic Heating Products
P.O. Box 14818 3633 I. Street
Philadelphia, PA 19134
www.crownboiler.com
D ESIGNED TO L EAD
Seitenansicht 0
1 2 3 4 5 6 ... 27 28

Inhaltsverzeichnis

Seite 1 - Bimini Buddy

Bimini Buddy NEAR-BOILER PIPING MODULE INSTALLATION INSTRUCTIONSModels:BB100H•BB100I•BB100C•WARNING: Improper installation, adjustment, alterat

Seite 2

89 Figures 5.0 - 5.8 show basic Bimini Buddy Piping piping for all types of Bimini Buddies. Please note the following:If the Bimini Buddy cannot be

Seite 3

89FIGURE 5.1: Installation Of Bimini Buddy at Same Level as Boiler Using Screw Driver VentFIGURE 5.0: Basic Bimini Buddy Field Piping (Bimini Buddy Sh

Seite 4 - II. Specications

1011Add the total equivalent length of the elbows determined in step 3 to the to the total straight pipe length 4) determined in Step 2. The result i

Seite 5 - 6HSDUDWRU

1011FIGURE 5.6: Boiler Loop Equivalent Length (Shaded) - BB100HTable 5.5: BB100C (Combi) Maximum Equivalent Boiler Loop Length Boiler Model Circulato

Seite 6 - Table 2.3: Connections

1213FIGURE 5.7 Boiler and IWH Loop Equivalent Length (Shaded) - BB100I

Seite 7 - 'LYHUWLQJ

1213FIGURE 5.8: Boiler Loop Equivalent Length (Shaded) - BB100C/BB100M

Seite 8 - IV. Location and Mounting

1415z Connect the domestic hot water piping as shown in Figure 6.0 for the BB100C. The components in this system and their functions are as follows:

Seite 9

1415FIGURE 6.0: BB100C Domestic Water PipingHose Bib ValveHose Bib Valve DHW Relief Valve(Max Setting 150 psi )Backflow Preventer Thermostatic Mixing

Seite 10 - V. Boiler and System Piping

1617WARNINGAllwiringandgroundingmustbedoneinaccordancewiththeauthorityhavingjurisdictionor,intheabsenceofsuch requirements, with th

Seite 11

1617FIGURE 7.1: Wiring BB100H to Boiler equipped with SolaFIGURE 7.0: Wiring BB100H to Boiler equipped with Type III MCBAHeating T-StatLINEBLRPUMPDHWP

Seite 13

1819Connecting BB100C to Type III MCBA Equipped boilers (Figure 7.4): 5) Connect the boiler circulator hot to the red lead and neutral (white) in the

Seite 14

1819FIGURE 7.3: Wiring BB100I to Boiler equipped with SolaFIGURE 7.4: Wiring BB100C to Boiler equipped with Type III MCBAHeating T-StatLINEBLRPUMPDHWP

Seite 15

2021VIII Start-upThe following steps must be taken in addition to those shown in the boiler instruction manual in order to commission the Bimini Buddy

Seite 16

2021FIGURE 7.5: Wiring BB100C to Boiler equipped with Sola+HDWLQJ76WDW/,1(%/53803'+:38036<63803+ 1 + 1 + 1 + 1%RLOHU&LUFXODWRU6\VWHP&a

Seite 17

2223To change the parameters shown in Table 8.0, using the keypad on the boiler to do the following:With the boiler powered, toggle the Mode key until

Seite 18 - VII. Wiring

2223Cover and Mounting Components - All ModelsKey DESCRIPTIONPART # QTY PART # QTY PART # QTY1Mounting Plate 230751 1 230751 1 230751 1

Seite 19 - Low Voltage

2425Piping Components - BB100HPiping Components - BB100I'&%$%&''&%$%&'

Seite 20

2425Piping Components - BB100C'&%$%&'

Seite 21

PN 980033 Rev. 11/04/11Manufacturer of Hydronic Heating ProductsP.O. Box 14818 3633 I. StreetPhiladelphia, PA 19134www.crownboiler.com

Seite 22 - VIII Start-up

1Table of Contents I. Product Description 2  II. Specications    2 III. Before Installing 6 IV. Locatio

Seite 23 - /RZ9ROWDJH

23I. Product Description The Bimini Buddy is a factory assembled near boiler piping module that is designed for use with Crown Bimini (BWC) series b

Seite 24 - IX. Parts

23FIGURE 2.1: Bimini Buddy (With Cover Installed )+\GUDXOLF6HSDUDWRU)%&'($'&%$%&'FIGURE 2.2: BB100H (Heat

Seite 25

45Table 2.3: Connections Key Model BB100H BB100I BB100CA From Boiler Supply 1” CopperB To Boiler Return 1” MPTC To System 1” CopperD From System 1” C

Seite 26 - Piping Components - BB100I

45FIGURE 2.6: BB100C (Combi -Shown with Cover Removed)FIGURE 2.5: BB100I (Indirect Water Heater - Shown with Cover Removed)Hydraulic Separator 3 Way D

Seite 27 - Piping Components - BB100C

67III. Before Installing Before installing this product:Verify that the planned installation will be in accordance with all local codes. In Massachuse

Seite 28 - Philadelphia, PA 19134

67THIS PAGE INTENTIONALLY LEFT BLANK

Kommentare zu diesen Handbüchern

Keine Kommentare